Sunrui Balclor BWMS Operation & Maintenance
Explore the Operational Intricacies
Embark on a journey through the operational intricacies and key maintenance practices for Sunrui’s cutting-edge Balclor BWMS BC-2500X2.
Premium SUNRUI BalClor BWTS Spare Parts Supplier
How Sunrui Balclor BWMS Works
Installed for automatic operation, the system prevents manipulation or bypassing, ensuring all activities are recorded. During ballasting, the Ballast pump draws water from the sea chest, passing it through the AFU for microorganism filtration. A side stream is then directed to the EDU, generating high-concentration oxidants like sodium hypochlorite. This solution is injected into the main manifold, effectively treating ballast water by killing plankton, spores, larvae, and pathogens to meet D-2 standards.
Key Maintenance Guidelines
Chlorine Treatment: After TRO treatment, chlorine must be removed and stored in a refrigerator until the next usage or replaced if its lifetime limit expires.
Auto Filter Cleaning: Clear the auto filters every 1-2 years based on system usage frequency.
Working Principle of Sunrui Balclor BWMS
Ballasting Phase
The Ballast pump draws water through the AFU for microorganism filtration. A side stream is sent to the EDU, generating sodium hypochlorite. This solution is then injecte